(1) on or after July 1, 1997, a customer of the utility located outside the limits of a municipality whose property is not located within one thousand (1,000) feet of a fire hydrant (measured from the hydrant to the nearest point on the property line of the customer) must be excluded from the increase in rates attributable to the change and . Between 132 kV and 330 kV. 0000004198 00000 n E1.4(c)(ii) generally requires the installation of fire hose reels on the storey they are to service. February 2021 Fire hydrant testing is a rolling program which tests water flow to confirm hydrants perform according to the Department of Energy and Water Supplys Planning Guidelines for water supply and sewerage. Fire safety Building fire safety Guidelines and information Fire safety Guidelines for the built environment Fire safety guidelines Access for fire brigade vehicles and firefighters (PDF) Emergency services information package and tactical fire plans (PDF) Fire hydrants for minor residential development (PDF) Fire safety in waste facilities (PDF) To cover Class A fire risks associated with a Class 2, 3 or 5 building or Class 4 part of a building. If the building is located a substantial distance from a fire brigade station equipped to utilise fire hydrants, E1.3(a)(ii) allows the building to be constructed without a fire hydrant system. 0000000016 00000 n January 2020 A blue cats eye on the road indicates their location. allows a smaller booster assembly protection wall than that required by clause 7.3(d)(iii) of AS 2419.1 where requirements set out in the provision are met. {pHG|Q 0000356943 00000 n What clearance around a hydrant should be left for emergency services to obtain access in an emergency? GL-42. To cover Class AE or E fire risks associated with emergency services switchboards. Don't place large heavy objects on top or next to the surface fitting. 216 0 obj <>stream November 2018 0000395504 00000 n The agreed method of maintenance could be established through the building manager or the tenancy contract. FRV Fire Safety Guideline - GL-38 - Decommissioning of Fire Hydrant and Sprinkler Systems (pdf) pdf 278.74 KB. 0000083040 00000 n hazardous processes or storage including the following: Cane furnishing manufacture, processing and storage. Ensure no one parks over the hydrant at any time. July 2019 The reason for this is to eliminate running a fire hydrant hose up or down a stairway. The 3-foot rule around the circumference is applicable in jurisdictions adopting the IFC, which includes the pumper connections. Esparto and other fibrous combustible material. 420 0 obj<>stream E1.4(a)(iii) does not require the installation of fire hose reels in a Class 9c building. July 2016 xref E1.9(a) requires the installation of suitable fire extinguishers in all buildings under construction. clearance between the lowest outlet and the . We pay our respect to their elders past and present and extend that respect to all Aboriginal and Torres Strait Islander peoples today. Exclusion zone*. Additional provision for special hazards must be made to allow for effective firefighting operations taking into consideration: Special fire hazards may exist for hazards under E1.10(a) in a warehouse used to store highly volatile or combustible materials, and also, at a site where highly combustible chemicals are manufactured. The notes to Table E1.5 also contain useful information on other Parts of the NCC requiring the installation of sprinklers within a building. E. de0D&DCbkom(naTc5. Our business is in South Australia. Parking rules and fines. 0000357136 00000 n Table E1.5 specifies when sprinklers are required in a building and which parts of the building must be sprinkler protected. 0000010029 00000 n NFPA 70 C. The length of any hydrant lead and six-inch dead-end service main shall not exceed 500 feet for any fire hydrant. In this instance, the restaurant tenant (the occupier) would ensure periodic maintenance on the fire extinguishers and coordinate the hydrant maintenance with other tenants. (1 kV = 1000 volts) Examples. A fire truck carries only enough water to make an initial fire attack. Additional information can be obtained by reference to the Standard, including an informative Appendix titled Guide to the Use of this Standard. All Class10 buildings (e.g. Power line voltage. To require the installation of suitable fire hose reel systems to enable, where appropriate, a buildings occupants to undertake initial attack on a fire. 0000312918 00000 n NFPA 497 <]/Prev 891759>> (b) The fire hydrant system (i) November 2019 0000285582 00000 n NFPA 770 (914 mm) clear space shall be maintained. MP 6.1 applies to multi-unit residential buildings (Class2) and holiday/business accommodation buildings (Class3), which are usually covered by body corporate arrangements for ongoing management and maintenance. October 2019 0000116277 00000 n August 2020 0000004128 00000 n Refer to the comment on EP1.6 for the reasons why the BCA requires the installation of fire control centres in buildings. NFPA 1 Fire Code 2018 Edition requirements for hydrant clearances are not required, unless specifically adopted as noted for the state of Florida and elsewhere. Parking signs show you where and when you can park or stop. June 2016. Fire hydrants are needed to prevent the spread of fire between buildings and fire compartments. 0000166065 00000 n 0000002870 00000 n Refer to the comment on EP1.5 for the reasons why the BCA requires the installation of firefighting equipment in buildings during their construction. Body corporate members should determine who is authorised to sign the yearly occupier's statement (DOCX, 31KB), on behalf of the body corporate and send it to the regional QFES office or email occupier.statements@qfes.qld.gov.au. Class 7 and Class 8 buildings have been included because of the potential size and severity of fires in such buildings. GL-43. It refers designers to the relevant Austroads publications for technical requirements, and outlines where Queensland Department of Transport and Main Roads practice supplements or differs from the Austroads guides. The Road Planning and Design Manual is the department's primary reference for the planning and design of roads. 0000007023 00000 n NFPA 495 To do so, they require appropriate means of extinguishment. combustible goods with an aggregate volume exceeding 1000 m. Combustible compressed fibreboards (low and high density) and plywoods. The hydrant cover should be clearly marked, cleared of vegetation or other obstructions and not parked over at any time. Designated work crews carry out a number of tasks, including: There may be a short water outage during planned hydrant work. If any conflict exists between AS 2444 and the BCA, then the BCA takes precedence. Clause 4.2 of AS 2419.1 requires a four hour water storage capacity for firefighting purposes. E1.1 has been left blank rather than renumber subsequent clauses. I have a fire hydrant in a planter curb, and we will have some trash enclosures nearby. This breeching inlet shall be within 18m from any fire engine accessible way or fire engine access road having minimum 4m width and within 50m from any wet E1.8(b) requires a fire control centre for Class 69 buildings with a total floor area of more than 18000 m2. Special Hazard Systems Refer to Fire safety for current advice. startxref Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2.2(3) and A2.4(3) as applicable. NFPA 1, Fire Code, requires the following clearance around fire hydrants: 18.5.7 Clear Space Around Hydrants. NFPA 13 Note: ONLY NON-PERMANENTLY HABITABLErooms such as garages located in proximity to the PMT will be considered in association with the application of this approachfor managing fire risk. 0000421079 00000 n Additional information can be obtained by reference to the Standard. To cover Class A fire risks in normally occupied less than 500 m. To cover Class A fire risks in classrooms and associated corridors in primary and secondary schools not provided with fire hose reels. HW[s~*aEU47]\Tz^Byd%X"X{tKw+ty #;M~e|9tF nQ%M\[R8Y=GOK2,20r0^.m.Wp 2%0n!=*q`Nqhqu8q\}d)SIv\_M.p\e5wV1eu2/sL/;CL?$AzDQ=*#]\)^wCdKz&'13C s AS 2419.1:2017 Fire Hydrant Installations - System Design, Installation and Commissioning (Opens in new window) Act(s) name Fire Service Act 1979 Tasmania NFPA 96 NOTE: - The requirements for maintenance are now contained in the Queensland Development Code MP6.1 Click . Please note - in the rare event of the water pipes leaking or bursting, repairs will be required and we will provide a quote for the work . be provided in front of each hydrant connection having a. diameter greater than 212 in. vinyl floor coverings. This testing helps determine the condition of fire hydrants. Standard 1851:2005 for the frequency of testing. This clause originally contained provisions relating to fire alarms. The National Construction Code (NCC) 2019 commenced in Victoria on 1 May 2019. Hydrant and water supply requirements for developments within standard QFES response area (PDF, 123KB) Physical protection of pillar hydrants (PDF, 119KB) Feed hydrant performance (PDF, 138KB) Dry fire hydrant system installation booster cabinet and signage (PDF, 137KB) Roller doors/shutters as access to achieve hydrant coverage (PDF, 119KB) September 2020 November 2017 Refer to the comment on EP1.4 for the reasons why the BCA requires the installation of sprinkler systems in buildings. NFPA 20 keep records of all maintenance for 2years with the building's fire safety management plan. Depending on the licence class held, existing licensees were . be provided in front of each hydrant connection having a Call: (03) 9764 0020 for more information about any fire protection . xbbg`b``3 ` [- 0000356140 00000 n Outdoor Storage of Baled Waste Paper. Class 9a health-care building used as a residential care building. 0000285648 00000 n QUEENSLAND REQUIREMENTS ELECTRICAL REQUIREMENTS To find out more contact FCF Fire & Electrical today Fire Regulations run by: ABN: 80 129 589 297 QBCC: 1137388 Regulations AS 2293 AS 1841 AS 1851 AS 1670 AS 2444 Queensland New South Wales Victoria South Australia Western Australia Northern Territory Australian Capital Territory Tasmania The concession not requiring the installation of fire hose reels in classrooms, etc is based on normal school use when teachers or school staff could be expected to be in control of students for the purpose of evacuation. Urban Utilities maintains more than 100,000 fire hydrants across five local council areas, including Brisbane, Ipswich, Scenic Rim, Lockyer Valley and Somerset. June 2018 March 2022 Table E1.5 requires sprinkler protection to Class 2 or 3 buildings (excluding a residential care building see other table items for residential care buildings) where the rise in storeys is 4 or more and the effective height is not more than 25 m. The requirements for these sprinkler systems are contained within Specification E1.5 and Specification E1.5a. These provisions emphasise the importance of the location of fire hose reels to ensure safety. 0000115622 00000 n Table E1.6 sets out when portable fire extinguishers are required in a building and the class of extinguisher to be used. Notes 1, 2 and 3 to Table E1.5 contain useful references to other BCA provisions that may require the installation of a sprinkler system. E1.4(a)(iv) does not require the installation of fire hose reels in classrooms and associated corridors of primary and secondary schools. A fire hydrant system must be provided to serve a building, having a total floor area greater than 500 m2; and, no more than 50 km from the building as measured along roads; and. NFPA 214 Queensland Fire and Emergency Services Fire Safety Management Tool for Owner/Occupiers Instructions For Use If you are an owner of, or a business or person occupying a building in Queensland, you have a legal obligation to ensure the safety of any person in that building in the event of a fire or hazardous material emergency. Fire apparatus access roads shall have an unobstructed width of not less than 20 feet (6096 mm), exclusive of shoulders, except for approved security gates in accordance with Section 503.6, and an unobstructed vertical clearance of not less than 13 feet 6 inches (4115 mm). 0 November 2022 Section 18.5 was revised in its entirety for the 2015 edition of the Code. This site is designed to be used with JavaScript. 0000003512 00000 n PE Prep Guide To clarify that the requirements of EP1.1 to EP1.6 will be satisfied if compliance is achieved with E1.1 to E1.10 in the case of all buildings, Part G3 in the case of buildings with an atrium, Part G4 in the case of buildings in alpine areas, Part G6 in the case of occupiable outdoor areas,Part H1 in the case of theatres, stages and public halls and Part H3 for farm buildings and farm sheds. NFPA 82 November 2020 NFPA 30 The other Deemed-to-Satisfy Provisions of Part E1 set out the required firefighting equipment and co-ordination facilities required in a building to deal with expected or usual hazards. equipped with equipment capable of utilising a fire hydrant. 0000046634 00000 n "F$H:R!zFQd?r9\A&GrQhE]a4zBgE#H *B=0HIpp0MxJ$D1D, VKYdE"EI2EBGt4MzNr!YK ?%_&#(0J:EAiQ(()WT6U@P+!~mDe!hh/']B/?a0nhF!X8kc&5S6lIa2cKMA!E#dV(kel }}Cq9 Note: wG xR^[ochg`>b$*~ :Eb~,m,-,Y*6X[F=3Y~d tizf6~`{v.Ng#{}}jc1X6fm;'_9 r:8q:O:8uJqnv=MmR 4 endstream endobj 419 0 obj<>/Size 399/Type/XRef>>stream Introduction to the National Construction Code (NCC), Part A3 Application of the NCC in States and Territories, Specification B1.2 Design of buildings in cyclonic areas, Specification C1.1 Fire-resisting construction, Specification C1.8 Structural tests for lightweight construction, Specification C1.10 Fire hazard properties, Specification C1.11 Performance of external walls in fire, Specification C1.13 Cavity barriers for fire-protected timber, Specification C2.5 Smoke-proof walls in health-care and residential care buildings, Specification C3.4 Fire doors, smoke doors, fire windows and shutters, Specification C3.15 Penetration of walls, floors and ceilings by services, Specification D1.12 Non-required stairways, ramps and escalators, Specification D3.6 Braille and tactile signs, Specification D3.10 Accessible water entry/exit for swimming pools, Specification E1.5 Fire sprinkler systems, Part E4 Visibility in an emergency, exit signs and warning systems, Specification E4.8 Photoluminescent exit signs, Specification F2.9 Accessible adult change facilities, Part F5 Sound transmission and insulation, Specification F5.5 Impact sound Test of equivalence, Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues, Part G5 Construction in bushfire prone areas, Specification H1.3 Construction of proscenium walls, Specification JVa Additional requirements, Part J7 Heated water supply and swimming pool and spa pool plant, Footnote: Other legislation and policies affecting buildings, Footnote: Other legislation affecting buildings, NSW Subsection J(A) Energy efficiency Class 2 building and Class 4 parts, NSW Part J(A)3 Air-Conditioning and ventilation systems, NSW Part J(A)5 Facilities for energy monitoring, NSW Subsection J(B) Energy efficiency Class 3 and Class 5 to 9 buildings, NT Part H102 Premises to be used for activities involving skin penetration, Qld Part G5 Construction in bushfire prone areas, Tas Part H109 Health service establishments, Tas Part H115 Premises for production or processing of isocyanates, Tas Part H116 Premises for electro-plating, electro-polishing, anodising or etching, Tas Part H117 Premises for lead processing, Tas Part H122 Early childhood centres and school age care facilities, Tas Part H124 Premises where work is undertaken on gas-fuelled vehicles, Schedule 5 Fire-resistance of building elements, Schedule 7 Fire Safety Verification Method, List of amendmentsNCC 2019Volume One Amendment 1. 0000210684 00000 n March 2020 detached house or townhouse). required or approved. They are basically needed for fire brigade use and are not intended for use by occupants. Fire Hydrant Fittings, Fire Hydrant Valves, Fire Hydrant Risers Pipe, Fire Hose Reels, Hydrant Boosters, Fire Cabinets of best quality. Check the building classes to make sure this information is relevant for you. It means that anyone using the fire hose will be able to get away quickly if the fire gets out of control. 0000045909 00000 n %%EOF Queensland Development Code (QDC) MP6.1 Commissioning and maintenance of fire safety installations (PDF, 100KB) outlines clear standards for maintaining fire safety installations. around the circumference of fire hydrants except as otherwise. 0000002339 00000 n These provisions are now covered in Part E2. October 2016 Vinyl, plastic, foamed plastic, rubber and other combustible sheets, offcuts and random pieces and rolled material storage, e.g. Fire apparatus access roads and public streets providing required access to buildings in accordance with Section 503 shall be provided with one or more fire hydrants, as determined by Section C102.1. for a Class 2, 3 or 5 building or Class 4 part of a building, provided, to serve the whole Class 2, 3 or 5 building or Class 4 part of a building where one or more internal fire hydrants are installed; or, where internal fire hydrants are not installed, to serve any fire compartment with a floor area greater than 500 m2, and for the purposes of this clause, a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building is considered to be a fire compartment; and. Urban Utilities has a renewal program to ensure hydrants across our network operate effectively. The changes modernise Queensland's fire protection licensing regime, ensure licensees have the necessary skills to carry out this critical work and reduce administration for licensees. February 2020 E1.3(b)(i)(C) 0000000749 00000 n The initial staff response to fire will always be through the more appropriate usage of portable fire extinguishers followed by evacuation. IFC/CFC 507.5.5 The nature of the initial fire response will also always require substation staff involvement prior to any fire brigade response. E1.4(d), (e) and (f) relates to the positioning of fire hose reels to help occupants attack a fire in its early stages. 0 Table E1.5 requires all buildings with an effective height of more than 25 metres, except those which only contain an open-deck carpark, to be sprinkler protected. 0000047022 00000 n Most licence classes automatically transitioned to the relevant new licence class. Once a building reaches a height of about 12 metres, firefighting in a building under construction becomes increasingly difficult. furniture factory. In the cases listed below, the door may remain open for the hose to pass through. Fire apparatus access roads shall have an unobstructed width of not less than 20 feet (6096 mm), exclusive of shoulders, except for approved security gates in accordance with Section 503.6, and an unobstructed vertical clearance of not less than 13 feet 6 inches (4115 mm). In Queensland, a Form 71 fire hydrant and sprinkler system commissioning test is used for the purposes of commissioning water-based fire safety installations, as required by the Queensland Development Code. Sorry, you need to enable JavaScript to visit this website. ADA However, it has small fibres that can cause fatal lung disease if inhaled and has now been banned. E1.8(a) requires all buildings with an effective height of more than 25 metres to be provided with a fire control centre. QFRS requires boosted on-site hydrants where a single street hydrant doesn't cover a fire compartment over 2000m2 in size. Such an arrangement would require the exit to be open, and therefore cause a significant risk of smoke entering. 2y.-;!KZ ^i"L0- @8(r;q7Ly&Qq4j|9 0000100799 00000 n NFPA 25 NFPA 110 Measure from the face of the hydrant to the wall. startxref Subscribe and learn something new each day: Get 100 Days of Free Sample Questions right to you. <<9037E3B2223CA945ADA1DA3E2C1BB8C8>]/Prev 834473/XRefStm 3340>> January 2019 July 2017 NFPA 415 NFPA 1 2018 Edition Class 6 and Class 9 buildings have been included because of their high potential fire load, and the likelihood of large populations unfamiliar with their layout or evacuation procedures. 18.5.7.2 A clear space of not less than 60 in. The use of water as an extinguishing medium in electricity network substations can cause extensive damage to the electricity assets and create increased hazards for firefighters. This eliminates the need to run a fire hose up or down a stairway. ASTM E1354 In every fire emergency, getting a hydrant to work is one of a firefighters' priorities. g. A 25-percent . You can help keep fire hydrants easily visible and accessible by: We appreciate your patience while this essential work is completed. The hydraulic design of the system is to comply with AS 2419.1 Clause 4.2 for a hydrant system and Please enable it to get the full experience. If there is no occupier, the building owner must sign the statement. To require the installation of suitable fire hydrant systems to facilitate the fire brigades firefighting operations. Suitable additional provision must be made if special problems of fighting fire could arise because of, the nature or quantity of materials stored, displayed or used in a building or on the allotment; or. The Building Fire Safety Regulation 2008 sets out the penalties for non-compliance with the code up to 30penalty units. There must be clearance of MIN 100mm around all handwheels Must be at least 750mm above FGL and no higher than 1200mm except when installed as an "I Pattern". July 2018 Booster systems incorporate a site-plan showing the location of all on-site hydrants. The fire hose reels can be located internally, externally or in any combination to achieve this coverage as set out in E1.4(e). However, it should be noted that where fire hose reels are not installed in these buildings, portable fire extinguishers must be installed in accordance with E1.6. Class 3 accommodation for children, aged persons and people with disabilities, including a Class 3 building used as a. For a Class 2, 3 or 5 building or Class 4 part of a building, E1.6(a)(ii) requires portable fire extinguishers to only be provided. a. 5'i`aqoq%8^.E#S1NxaF3z}cI ]Ill~NFa\[;+NK)4&qeNI;(fYr:WLg#T=$o[27=4yAvgIed$gxPNVUw,/8[WTqEjQeDOXlC#by~,*Ye(]\ %w=~2VX72}[7BY!t+%B6WIl;vNzijnnipH=sq%|"IL4&@ The National Construction Code 2019 sets out that a fire hydrant system must be provided to the degree necessary to facilitate the needs of the fire brigade appropriate to fire-fighting operations, the floor area of the building and the fire hazard. 0000046518 00000 n 0000395281 00000 n Safety equipment; Preparedness; Safety in living and entertainment spaces; Electrical safety around water Daily Discussion Copyright 2022. Portable fire extinguishers provided in a Class 2 or 3 building or Class 4 part of a building must be, distributed outside a sole-occupancy unit, to serve only the storey at which they are located; and. 0000245067 00000 n Grease Duct Zero-Clearance (Rated Shaft or Duct Wrap System) - Grease Duct Wrap Systems Require First Layer and 2nd Layer Inspections Hood Air Balance (Fire Department Must Witness 3rd Party Test) Kitchen Ventilation System Final Brian Alkire Assistant Chief of Fire Prevention Email Fire Prevention Bureau 443 N. 4th Street Lafayette, IN 47901 0000358734 00000 n December 2021 Provisions for Class 1 and Class 10 buildings are now covered in Volume Two. 0000003740 00000 n *-;qqc'Ve+zRo_l.])(ZZvU/y>l&ZUKt!=UMb!6's:UgFeh'J4oplv1ZWFlc}i={Y#>//.ny=C'W%}%o_5?J%I55 +07 >w#e!t_m}ZA9Y must be installed in accordance with AS 2419.1, except, a Class 8 electricity network substation need not comply with clause 4.2 of AS 2419.1 if, it cannot be connected to a town main supply; and, one hour water storage is provided for fire-fighting; and, where a sprinkler system is installed throughout a building in accordance with AS 2118.1, AS 2118.4, AS 2118.6, FPAA101H or FPAA101D the fire hydrant booster protection requirements of clauses 7.3(c)(ii) and 7.3(d)(iii) of AS 2419.1 do not apply; and, a fire hydrant booster assembly may be located between 3.5 m and 10 m of the building, and need not comply with clause 7.3(d)(iii) of AS 2419.1 where the assembly is protected by an adjacent fire-rated freestanding wall that, achieves an FRL of not less than 90/90/90; and, extends not less than 1 m each side of the outermost fire hydrant booster risers within the assembly and is not less than 3 m wide; and, extends to a height of not less than 2 m above finished ground level; and, where internal fire hydrants are provided, they must serve only the storey on which they are located except that a sole-occupancy unit, in a Class 2 or 3 building or Class 4 part of a building may be served by a single fire hydrant located at the level of egress from that sole-occupancy unit; or. 0000002149 00000 n NFPA 68 In the first minutes of a fire emergency a continuous water supply from the water mains must be accessed through at a hydrant. 0000018577 00000 n Design Documents 0000420683 00000 n <<0558314FE9A18C429F2D8FB4CF1D15E9>]>> inadequate water supply for firefighting. around the circumference of fire hydrants except as otherwise An exemption is also granted to smaller Class 8 electricity network substations within a multi-classified building as they are provided with additional fire protection measures to compensate for the removal of sprinklers. 0000003572 00000 n Explanatory information: Cross-volume considerations, Part A5 Documentation of design and construction, Specification C1.13a Fire-protected timber, Part D3 Access for people with a disability, Specification E1.5a Class 2 and 3 buildings not more than 25 m in effective height, Part E2 Smoke hazard management (Performance Requirements), Part E2 Smoke hazard management (Deemed-to-Satisfy Provisions), Specification E2.2a Smoke detection and alarm systems, Specification E2.2b Smoke exhaust systems, Specification E2.2d Residential fire safety systems, Part E4 Visibility in an emergency, exit signs and warning systems (DtS), Part F2 Sanitary and other facilities (DtS), Part F5 Sound transmission and insulation (DtS), Specification F5.2 Sound insulation for building elements, Part G1 Minor structures and components (DtS), Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues (DtS), Specification G2.2 Installation of boilers and pressure vessels, Specification G3.8 Fire and smoke control systems in buildings containing atriums, Part G4 Construction in alpine areas (DtS), Part G5 Construction in bushfire prone areas (DtS), Part J5 Air-conditioning and ventilation systems, Specification J1.5a Calculation of U-Value and solar admittance, Specification J1.5b Spandrel panel thermal performance, Specification J1.6 Sub-floor thermal performance, Specification J6 Lighting and power control devices, NSW Part H101 Entertainment venues other than temporary structures and drive-in theatres, Tas Part H114 Premises for manufacture or processing of glass reinforced plastics, 1.4 Design scenarios: NCC Performance Requirements, AS 2419.1 subject to concessions granted under and.
Andy Lecompte Net Worth, Nuns Buried Babies In Walls, Branden Michael Wolfe Political Affiliation, Patxi's Pizza Nutritional Information, Kyle Richards' Aspen House, Articles F